This study was conducted as a test-retest investigation to assess the reliability of the methods prior to a planned study on the same topic. Ten volunteer participants were recruited from among employees at Sodersjukhuset (South General Hospital). The radial aspects of the second and fourth digits on both hands were examined using static two-point discrimination (S2PD) and sensory neurography on two separate occasions. The results from the two separate measurements will be analysed with an Intra Class Coefficient analysis and a Bland-Altman test.
A neurophysiological examination can objectively measure remaining function in an injured digital nerve. Using this method, axons that are still able to conduct an action potential are assessed. The response can be measured as the amplitude (the summed action potentials from the nerve's axons) and as the area (the amount of functioning axons). The area is a somewhat more precise measurement method, as it includes all axons, both those with low and high conduction velocities. Amplitude measurements may give falsely low values if nerves with poorer degrees of myelination are included in the measurement. Amplitude is measured in µV (microvolt) and area in µV/ms (microvolt per millisecond). The method currently used to assess discriminative sensation is the S2PD-test. In this test two pins are pressed perpendicular and longitudinally on each side of the fingertip. The pins can consist of an unfolded paper clip or a factory-made discriminator. The distance between the two pins, where it is possible to discriminate between one or two pins, is the S2PD. The test is influenced by many external factors, such as the clinician's level of experience, the patient's desire to give the correct answer, language barriers, and similar issues. Furthermore, this examination method does not clarify what is actually being measured beyond the patient's subjective discriminative sensation. If neurophysiological assessment is used as a complement to S2PD and can provide an objective measurement tool with high reliability and reproducibility, it could become an important addition to the clinical arsenal for follow-up after nerve injury. Such knowledge would make it easier to clinically evaluate, understand, and monitor the healing process of the injured nerve. It would also facilitate the assessment and systematic follow-up of treatment outcomes. The participants will be examined at the Hand Surgery Clinic at South General Hospital at two separate occasions separated. Each visit is estimated to last approximately 60 minutes. It will include assessment using S2PD and neurophysiological examination of the radial side of the second and fourth fingers on both hands. Finger temperature will be measured using an infrared thermometer (Testo 826-T2), and, if necessary, the fingers will be warmed (using a water bath, heating pad or something similar) to a target temperature of a minimum of 32 °C. The hands will then be gently abraded using a preparation gel (NuPrep). Conductive gel (Ten20) will be applied to the electrodes. A recording electrode will be placed volarly over the wrist, a ground electrode in the palm, and the stimulating electrode on the radial side of the finger (digits II and IV). Electrical stimulation will be delivered in an orthodromic direction, from the finger toward the wrist. The stimulus intensity will be gradually increased until no further increase in amplitude is observed/amplitude is stable. At the first visit, the examination begins with S2PD followed by sensory neurography. At the second visit, the order of the assessments is reversed to minimize potential crossover effects.
see section "study description"
see section "study description"
Department of Hand Surgery, Södersjukhuset Hospital, Stockholm, Sweden
Stockholm, Sweden
Reliability of method: Sensory neurography measurements (AREA) performed on two separate occasions.
ICC (Intraclass correlation coefficient) will be used to assess correlation between measurements at baseline and 2 weeks
Time frame: Measures will be assessed at baseline and 2 weeks.
Assessment of agreement AREA
The Bland-Altman method will be used to assess whether the measurement method demonstrates sufficient agreement to be considered reliable. The predefined limit for acceptable differences between measurements is 50%.
Time frame: Measurements will be performed at baseline and at 2 weeks.
Reliability of method: Sensory neurography measurements (SNAP) performed on two separate occasions
ICC (Intraclass correlation coefficient) will be used to assess whether the measurement method demonstrates sufficient correlation to be considered reliable.
Time frame: Measures will be assessed at baseline and 2 weeks.
Assessment of agreement SNAP
The Bland-Altman method will be used to assess whether the measurement method demonstrates sufficient agreement to be considered reliable. The predefined limit for acceptable differences between measurements is 50%.
Time frame: Measurements at baseline and 2 weeks