This experimental physiologic study is conducted to determine the effect of different mechanical ventilation settings (in terms of positive end-expiratory pressure) on patients receiving mechanical ventilation with expiratory flow obstruction and autoPEEP. The main question it aims to answer In patients with autoPEEP, what is the effect of applying external PEEP on gas exchange and the lung emptying pattern in patients with total ventilatory support? Participants must comply: \- Age \> 17 years. * Invasive mechanical ventilation (endotracheal tube or tracheostomy) in controlled mode, with SpO2 \> 90%, for more than 12 hours. * No contraindications for abdominal compression. * Presence of autoPEEP greater than 3 cmH2O measured in mechanical ventilation with total support and ZEEP. * Total mechanical respiratory support, without respiratory muscle activity (inspiratory or expiratory).
The study includes patients with controlled mechanical ventilation and autoPEEP. By programming different levels of external PEEP, its effect on respiratory mechanics, gas exchange, and pulmonary emptying constants will be determined. Once included in the study, participants remain on the established mechanical ventilation schedule.Subsequently, they will remain for 5 minutes at each programmed PEEP level, during which the variables under study will be recorded. They will remain at 3 PEEP levels for 15 minutes before taking arterial blood gas samples. The variables under study will be recorded and stored in a respiratory monitor and an electrical impedance tomograph, and subsequently analyzed offline.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
20
External PEEP will be increased by 3 cmH₂O, from 0 to 15 cmH₂O.
Hospital Santojanni
Buenos Aires, Argentina
To evaluate the expiratory time constant as a function of external PEEP.
Methodology: the expiratory pattern is defined through the expiratory time constant at different PEEP levels relative to the reference (ZEEP).
Time frame: 1 hour
To evaluate thel effect of external PEEP in gas exchange respect to reference (ZEEP)
Gas exchange: Methodology: Arterial blood gas samples (PaO2 and PaCO2 in mmHg) are taken after a 15-minute stability period at three time points: without external PEEP (reference), and 3 cmH2O below and 3 cmH2O above final PEEP.
Time frame: 1 hour
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.