The goal of this clinical trial is to learn if a high-flow nasal cannula (HFNC) - a device that delivers warm, humidified air through a small tube placed in the nostrils - can improve exercise tolerance in adults with heart failure (HF) who are entering a cardiac rehabilitation program. The main questions it aims to answer are: Can HFNC help people with heart failure exercise for a longer time during a treadmill test? and does HFNC lower how hard people feel they are working during exercise? Researchers will compare exercise performance with HFNC to exercise performance without HFNC to see if HFNC helps people with HF tolerate exercise better. Participants will: Complete two treadmill exercise tests, one with HFNC and one without, in a randomly assigned order. Wait 48 to 72 hours between the two tests to allow full recovery. Have their heart rate, blood pressure, oxygen level, and breathing rate measured before and after each test.
Heart failure is a chronic syndrome characterized by reduced cardiac output, exercise intolerance, and dyspnea. Despite the well-established benefits of cardiac rehabilitation, many HF patients have severely limited exercise capacity, which restricts the intensity and duration of training they can safely perform. High-flow nasal cannula (HFNC) delivers heated, humidified air at flow rates of 50-60 L/min. Its physiological effects include reduction of inspiratory work, washout of nasopharyngeal dead space, generation of positive end-expiratory pressure, and improved mucociliary transport. These mechanisms may facilitate exercise in patients with cardiorespiratory limitations. STUDY DESIGN. Randomized crossover trial. Each participant acts as their own control, completing two incremental treadmill tests in random order, separated by a washout period of 48-72 hours: Condition A (experimental): HFNC via AIRVO 2™ device (Fisher \& Paykel Healthcare) with asymmetric nasal cannula at 50-60 L/min, FiO₂ 0.21, temperature 34-37°C. Condition B (control): no ventilatory support device. Randomization will be performed using randomizer.org. Before the experimental condition, participants will undergo an acclimatization period in which flow is increased by 10 L/min every 5-10 minutes until reaching the target flow or maximum tolerated flow. EXERCISE PROTOCOL. An incremental protocol will be used on the treadmill, which will consist of incline and a progressive increase in speed and grade. The test ends at voluntary exhaustion or when predefined safety stopping criteria are met. SAFETY. The test will be stopped if any of the following occur: chest pain, severe dyspnea (Borg ≥8), nausea or presyncope, cyanosis, SpO₂ below 90%, or heart rate above 85% of age-predicted maximum. The testing site will be equipped with automated external defibrillator, bag-valve mask, emergency oxygen, and at least one team member certified in advanced life support. Direct transfer to the hospital emergency service is available on-site (Complejo Hospitalario San José). OUTCOMES. Primary outcomes are maximum treadmill test duration (seconds) and perceived exertion (Modified Borg Scale, 0-10), measured immediately after each test. Secondary outcomes - blood pressure, heart rate, SpO₂, respiratory rate, and rate-pressure product - are measured at baseline and immediately post-test. STATISTICAL ANALYSIS. Data normality will be assessed using the Shapiro-Wilk test (n\<50). Paired t-test or Wilcoxon signed-rank test will be applied depending on data distribution. Sample size was calculated for a crossover design (two-tailed, α=0.05, power=80%, dz=0.8), yielding 23 participants; 28 will be recruited assuming 20% dropout. CO-INVESTIGATORS: Monserrat Delgado Valverde, Monserrat Orellana Morales, Emily Quiñileo Riffo, and Sergio Silva Valverde (Escuala de Kinesiología, Universidad de Santiago de Chile). Claudia Román Ureta, Paulina Castro Olivares (Complejo Hospitalario San José). SETTING. Cardiovascular rehabilitation program, Complejo Hospitalario San José, Independencia, Santiago, Chile.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
BASIC_SCIENCE
Masking
NONE
Enrollment
28
HFNC delivered via AIRVO 2™ (Fisher \& Paykel Healthcare, Auckland, New Zealand) with a nasal cannula at 50-60 L/min, FiO₂ 0.21, temperature 34-37°C. The cannula is removed immediately after the test is completed.
Complejo Hospitalario San José
Santiago, Santiago Metropolitan, Chile
Maximum treadmill test duration
Maximum time achieved by the participant during the incremental treadmill test, measured in seconds
Time frame: Immediately after each test session (up to 24 minutes)
Perceived exertion
Participant's subjective perception of effort measured using the Modified Borg Scale (0-10), where 0 is nothing at all and 10 is extremely heavy
Time frame: Immediately after each test session
Heart rate
Heart rate measured in beats per minute using pulse oximetry
Time frame: Baseline and immediately after each test session
Blood pressure
Systolic and diastolic blood pressure measured in mmHg using a sphygmomanometer
Time frame: Baseline and immediately after each test session
Oxygen saturation
Peripheral oxygen saturation (SpO₂) measured as a percentage using pulse oximetry
Time frame: Baseline and immediately after each test session
Respiratory rate
Respiratory rate measured in breaths per minute using a vital signs monitor
Time frame: Baseline and immediately after each test session
Rate-pressure product
Calculated as systolic blood pressure multiplied by heart rate (mmHg × beats/min), used as an indirect indicator of myocardial oxygen demand
Time frame: Baseline and immediately after each test session
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.