Aim of the Study The aim of this study is to compare between two forms of magnetic attachments in implant retained mandibular over-dentures.
Complete edentulism of the mandible is frequently associated with compromised denture retention and stability, which may negatively affect mastication, comfort, and patient satisfaction. Mandibular implant-supported overdentures retained by magnetic attachments have been introduced as a reliable treatment option to improve prosthesis retention and function. Different magnetic attachment designs are available, including flat and dome-shaped configurations. The geometry of magnetic attachments may influence retentive behavior, stress distribution, and overdenture stability during function. However, clinical evidence comparing the retention performance of these attachment designs remains limited. This randomized clinical trial will include 14 completely edentulous patients aged 50-65 years. All participants will receive two implants placed in the canine regions of the mandible using a fully guided surgical protocol. After a 3-month healing period, patients will be randomly allocated into two equal groups according to the magnetic attachment design used. Group I will receive flat magnetic attachments, while Group II will receive dome-shaped magnetic attachments. The primary outcome measure will be overdenture retention evaluated using a digital force gauge. Retention measurements will be performed at the time of overdenture loading (baseline), after 3 months of functional use, and after 6 months of functional use. The results will be used to determine whether magnetic attachment design influences the retention of mandibular implant-supported overdentures.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
14
Flat magnetic attachment system used for retention of mandibular implant-supported overdentures. The system consisted of a Dentium MKP5530 keeper and MGT5520 magnetic assembly with a manufacturer-reported retentive force of 700 gf.
Dome-shaped magnetic attachment system used for retention of mandibular implant-supported overdentures. The system consisted of a Dentium MKP5530D keeper and MGT5520D magnetic assembly with a manufacturer-reported retentive force of 700 gf.
Faculty of Dentistry, Ain Shams University
Cairo, Egypt
Overdenture Retention Force
Retention force of mandibular implant-supported overdentures retained by flat and dome-shaped magnetic attachments, measured in Newtons (N) using a digital force gauge during vertical dislodgement.
Time frame: Baseline, 3 months, and 6 months after overdenture loading
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.