This prospective single-center study evaluates the effect of dry eye disease and short-term ocular surface treatment on the agreement and repeatability of corneal astigmatism measurements in patients with age-related cataract. Participants undergoing preoperative cataract evaluation are classified into a control group or a dry eye disease group according to ocular surface symptoms and objective tear film findings. All participants undergo ocular surface assessment and repeated corneal measurements using three commonly used devices: IOLMaster 700, Pentacam AXL, and iTrace Prime. Measurements include keratometric corneal astigmatism, total corneal astigmatism, and vector components of astigmatism. Patients with dry eye disease receive 0.3% sodium hyaluronate eye drops four times daily for 2 weeks, after which ocular surface assessment and device measurements are repeated. The primary objective is to determine whether dry eye disease reduces interdevice agreement and test-retest repeatability of corneal astigmatism measurements, and whether short-term ocular surface treatment improves measurement stability. Interdevice agreement is assessed using Bland-Altman analysis, and repeatability is evaluated using within-subject standard deviation, test-retest repeatability, and intraclass correlation coefficient.
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
400
0.3% sodium hyaluronate eye drops administered four times daily for 2 weeks in participants with dry eye disease.
Eye and ENT hospital of Fudan University
Shanghai, Shanghai Municipality, China
RECRUITINGInterdevice Agreement of Corneal Astigmatism Measurements
Interdevice agreement of corneal astigmatism measurements among IOLMaster 700, Pentacam AXL, and iTrace Prime will be assessed using Bland-Altman analysis. Pairwise comparisons will be performed for IOLMaster 700 versus Pentacam AXL, IOLMaster 700 versus iTrace Prime, and Pentacam AXL versus iTrace Prime. The main parameters include keratometric corneal astigmatism, total corneal astigmatism, and their vector components J0 and J45. The mean difference and 95% limits of agreement will be calculated.
Time frame: Baseline and 2 weeks after ocular surface treatment in the dry eye disease arm.
Test-Retest Repeatability of Corneal Astigmatism Measurements
Test-retest repeatability of corneal astigmatism measurements obtained using IOLMaster 700, Pentacam AXL, and iTrace Prime will be evaluated using three consecutive valid measurements from each device. The main parameters include keratometric corneal astigmatism, total corneal astigmatism, and their vector components J0 and J45. Repeatability will be assessed using within-subject standard deviation, test-retest repeatability calculated as 2.77 times the within-subject standard deviation, and intraclass correlation coefficient with 95% confidence intervals.
Time frame: Baseline and 2 weeks after ocular surface treatment in the dry eye disease arm.