this study aims to investigate the efficacy and safety of PADN therapy compared with standard medical therapy in patients diagnosed with pulmonary hypertension after M-TEER, thereby providing evidence for clinical treatment decision-making
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
60
\*\*PADN Procedure Steps:\*\* 1. Non-Selective Pulmonary Artery Angiography 2. PADN Ablation Target Selection 3. Hemodynamic Assessment 4. Establishment of the PADN® RF Catheter Delivery Rail 5. PADN® RF Catheter Delivery 6. Performance of the PADN Procedure While maintaining the transseptal sheath position unchanged, the PADN® RF catheter is gently and slowly withdrawn and rotated (either clockwise or counterclockwise) to bring any three of the No. 2-9 electrodes into close apposition with the three target ablation points A, B, and C. . Temperature-controlled mode is recommended for radiofrequency ablation, with the ablation temperature set to 50°C and the total ablation time set to 150 seconds. The pulmonary artery radiofrequency ablation generator will automatically start calculating the effective ablation time (ET) once the ablation temperature reaches 45°C. Ablation at each target point is considered effective when the ET reaches at least 120 seconds. 7. Completion of the PADN
Control group (receiving standard medical therapy alone)
Structural Heart Disease Unit, Xiamen Cardiovacular Hospital
Xiamen, Fujian, China
RECRUITINGClinical worsening event
defined as the occurrence of any of the following: 1. Worsening heart failure symptoms requiring intravenous therapy (inotropes, diuretics, or vasodilators); 2. Heart failure-related rehospitalization; 3. Decrease in 6MWD from baseline by \>10% or \>30 meters; 4. Need for heart/lung transplantation; 5. All-cause death
Time frame: From enrollment up to 12 months
Changes from baseline in pulmonary vascular resistance (right heart catheterization)
Changes from baseline in pulmonary vascular resistance (PVR); Unit of measure: Wood units
Time frame: From enrollment up to 12 months
Changes from baseline in echocardiographic linear dimension parameters
Changes from baseline in right atrial diameter (RAD), left atrial diameter (LAD), left ventricular internal diameter at end-diastole (LVIDd), left ventricular posterior wall thickness at end-systole (LVPWd), and tricuspid annular plane systolic excursion (TAPSE); Unit of measure: millimeters (mm)
Time frame: From enrollment up to 12 months
Changes from baseline in echocardiographic percentage functional indices
* Parameters: Ejection fraction (EF), right ventricular fractional area change (RV-FAC) * Unit of measure: percentage (%)
Time frame: From enrollment up to 12 months
Changes from baseline in cardiac output (right heart catheterization)
* Parameter: Cardiac output (CO) * Unit of measure: liters per minute (L/min)
Time frame: From enrollment up to 12 months
Changes from baseline in WHO functional class
Time frame: From enrollment up to 12 months
Changes from baseline in NT-proBNP/BNP
Time frame: From enrollment up to 12 months
Changes from baseline in 6-minute walk distance (6MWD)
Time frame: From enrollment up to 12 months
Changes from baseline in Short Form-36 (SF-36) Health Survey scale score
The SF-36 scale ranges from 0 to 100, where higher scores indicate a better outcome (Minimum = 0, Maximum = 100).
Time frame: From enrollment up to 12 months
All-cause rehospitalization rate
Time frame: From enrollment up to 12 months
Incidence of worsening heart failure symptoms requiring intravenous therapy
Time frame: From enrollment up to 12 months
Heart failure-related rehospitalization rate
Time frame: From enrollment up to 12 months
Rate of need for heart/lung transplantation
Time frame: From enrollment up to 12 months
Changes from baseline in intracardiac pressure parameters (right heart catheterization)
* Parameters: mean right atrial pressure (mRAP), right ventricular systolic pressure (RVSP), pulmonary artery systolic pressure (PASP), pulmonary artery diastolic pressure (PADP), mean pulmonary artery pressure (mPAP), pulmonary artery wedge pressure (PAWP) * Unit of measure: millimeters of mercury (mmHg)
Time frame: From enrollment up to 12 months
Changes from baseline in cardiac index (right heart catheterization)
* Parameter: Cardiac index (CI) * Unit of measure: liters per minute per square meter (L/min/m²)
Time frame: From enrollment up to 12 months
Changes from baseline in pulmonary arterial compliance (right heart catheterization)
* Parameter: Pulmonary arterial compliance (PAC) * Unit of measure: milliliters per millimeter of mercury (mL/mmHg)
Time frame: From enrollment up to 12 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.