Background: Rotational atherectomy (RA) generates high-intensity drilling noise concentrated around 3000 Hz, creating a distinctive auditory stressor that may exacerbate perioperative anxiety and autonomic dysregulation in patients undergoing percutaneous coronary intervention. Despite growing evidence linking procedural noise to adverse psychological and physiological outcomes, targeted noise-reduction interventions in the cardiac catheterization laboratory remain unexplored. Aims: To investigate the effects of intraoperative artificial intelligence-enabled active noise cancellation (AI ANC) headphones on state anxiety, autonomic nerve function assessed by heart rate variability (HRV), and hemodynamic stability in patients undergoing RA. Methods: This prospective, randomized, assessor-blinded, controlled trial enrolled 100 patients undergoing elective RA between January and June 2026 at a tertiary hospital in Shandong Province, China. After screening 120 consecutive patients, 100 eligible participants were randomized 1:1 to the experimental group (AI ANC headphones \[Sony WH-1000XM6\] plus standard care, n=50) or the control group (standard care alone, n=50). The primary outcome was the change in state anxiety (S-AI) score from baseline to post-procedure. Secondary outcomes included noise disturbance visual analogue scale (VAS), patient satisfaction, HRV indices (time-domain: SDNN, RMSSD; frequency-domain by autoregressive \[AR\] model and fast Fourier transform \[FFT\] as reference), hemodynamic fluctuations (MAP, HR, SpO2), incidence of symptomatic coronary spasm, and intraoperative vasodilator consumption. Continuous ECG was recorded via Polar H10 chest strap; HRV was analyzed using Kubios HRV Scientific 4.3. All analyses followed the intention-to-treat principle.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
SUPPORTIVE_CARE
Masking
SINGLE
Enrollment
100
Commercially available over-ear ANC headphones with adaptive AI-driven noise cancellation and voice-passthrough mode. Set to ANC mode throughout the procedure. A palm placed on the right earcup temporarily activates conversation mode; releasing the hand restores full noise cancellation.
Qilu Hospital of Shandong University
Jinan, Shandong, China
Change in State Anxiety Score from Baseline to Post-Procedure (S-AI Change Score)
State anxiety is assessed using the state subscale of the Chinese version of the State-Trait Anxiety Inventory (STAI Form Y; Spielberger et al., 1983). The S-AI comprises 20 items each rated on a 4-point Likert scale (total score range: 20-80), with higher scores indicating greater state anxiety. Internal consistency (Cronbach's alpha) = 0.83-0.93. The scale is administered at two time points: Baseline (T0) - after admission to the preoperative area and before initiation of rotational atherectomy; Post-procedure (T1) - after sheath removal and before leaving the catheterization laboratory. The primary metric is the change score: delta S-AI = T1 minus T0 (negative values indicate anxiety reduction).
Time frame: baseline (pre-procedure) and immediately after the procedure
Perceived Noise Disturbance on Visual Analogue Scale (VAS)
immediately after the procedure, the patient rates: "How disturbing was the procedural noise?" on a 1-10 horizontal VAS (1 = not disturbing at all; 10 = extremely disturbing)
Time frame: immediately after the procedure
Overall Procedural Satisfaction on Visual Analogue Scale (VAS)
immediately after the procedure, the patient rates overall satisfaction with the procedural experience on a 1-10 VAS (1 = completely dissatisfied; 10 = completely satisfied).
Time frame: immediately after the procedure
Standard Deviation of Normal-to-Normal R-R Intervals (SDNN) During Rotational Atherectomy
Continuous beat-to-beat R-R interval data (at least 5 minutes) recorded throughout the Rotational Atherectomy procedure using the Polar H10 chest strap (sampling rate: 1000 Hz). Raw data analyzed using Kubios HRV Scientific version 4.3 (Kubios Oy, Kuopio, Finland) with automatic artefact correction at the 'Very Low' threshold. SDNN reflects overall autonomic regulatory capacity.
Time frame: during the rotational atherectomy procedure
Root Mean Square of Successive R-R Interval Differences (RMSSD) During Rotational Atherectomy
Calculated from the same at-least-5-minute R-R interval recording using Kubios HRV Scientific 4.3. RMSSD specifically captures vagally mediated beat-to-beat modulation of heart rate.
Time frame: during the rotational atherectomy procedure
High-Frequency (HF) Power and Low-Frequency/High-Frequency (LF/HF) Ratio by Autoregressive (AR) Spectral Analysis During Rotational Atherectomy
Frequency-domain analysis performed using AR modeling (primary method, 16th-order model) and FFT (reference method, Welch's periodogram). HF power (0.15-0.40 Hz, ms2) primarily reflects respiratory-mediated vagal efferent activity. VLF power excluded per Task Force recommendations. Bonferroni correction (adjusted alpha = 0.00625) applied to frequency-domain indices.
Time frame: during the rotational atherectomy procedure
Maximum Mean Arterial Pressure (MAP) Fluctuation Amplitude During Rotational Atherectomy
MAP monitored continuously via radial arterial sheath. Maximum fluctuation amplitude = maximum MAP minus minimum MAP during the RA procedure (mmHg).
Time frame: during the rotational atherectomy procedure
Maximum Heart Rate (HR) Fluctuation Amplitude During Rotational Atherectomy
HR derived from continuous three-lead electrocardiography. Maximum fluctuation amplitude = maximum HR minus minimum HR (bpm). Mean HR and minimum/maximum HR also reported.
Time frame: during the rotational atherectomy procedure
Incidence of Symptomatic Coronary Artery Spasm During Rotational Atherectomy
Defined as transient coronary lumen narrowing greater than 50 percent compared to baseline angiography, accompanied by chest pain and/or ST-segment changes, requiring vasodilator administration.
Time frame: during the rotational atherectomy procedure
Cumulative Intraoperative Dose of Vasodilator Agents (Nitroglycerin, Adenosine)
Total administered dose (micrograms) of nitroglycerin and/or adenosine during the RA procedure, abstracted from the procedural medication record.
Time frame: during the rotational atherectomy procedure
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.