Rapid sequence intubation (RSI) is the standard approach for emergency airway management in critically ill patients requiring endotracheal intubation. Laryngoscopy and tracheal intubation may provoke significant hemodynamic responses, including increases in heart rate and blood pressure, which may adversely affect patients with severe neurological or cardiovascular disease. Although hemodynamic responses during tracheal intubation have been extensively investigated in the anesthesiology literature, evidence from emergency department settings remains limited. Furthermore, previous studies have rarely confirmed whether an adequate depth of anesthesia had been achieved before laryngoscopy, making interpretation of hemodynamic responses difficult. The aim of this prospective observational study is to evaluate hemodynamic responses during rapid sequence intubation in adult emergency department patients after confirming adequate depth of anesthesia using bispectral index (BIS) monitoring. Heart rate and blood pressure will be recorded before induction, during intubation, and after successful endotracheal intubation, allowing objective assessment of the hemodynamic response under confirmed adequate anesthetic depth.
Rapid sequence intubation (RSI) is the standard approach for emergency airway management in critically ill patients requiring endotracheal intubation. Laryngoscopy and tracheal intubation may provoke significant hemodynamic responses, including increases in heart rate and blood pressure, which may adversely affect patients with severe neurological or cardiovascular disease. Although hemodynamic responses during tracheal intubation have been extensively investigated in the anesthesiology literature, evidence from emergency department settings remains limited. Furthermore, previous studies have rarely confirmed whether an adequate depth of anesthesia had been achieved before laryngoscopy, making interpretation of hemodynamic responses difficult. The aim of this prospective observational study is to evaluate hemodynamic responses during rapid sequence intubation in adult emergency department patients after confirming adequate depth of anesthesia using bispectral index (BIS) monitoring. Heart rate and blood pressure will be recorded before induction, during intubation, and after successful endotracheal intubation, allowing objective assessment of the hemodynamic response under confirmed adequate anesthetic depth.
Study Type
OBSERVATIONAL
Enrollment
200
Bispectral index monitoring is used to assess the depth of anesthesia before laryngoscopy. Endotracheal intubation is performed after an adequate BIS value has been achieved.
Akdeniz University Hospital
Antalya, Turkey (Türkiye)
RECRUITINGChange in Diastolic Blood Pressure Following Rapid Sequence Intubation
Diastolic Blood pressure (MAP) measured before induction, immediately after endotracheal intubation, and at 5, 10, and 15 minutes after intubation in patients with BIS-confirmed adequate depth of anesthesia.
Time frame: Baseline, immediately after intubation, and 5, 10, and 15 minutes after intubation
Change in Systolic Blood Pressure Following Rapid Sequence Intubation
Systolic Blood pressure measured before induction, immediately after endotracheal intubation, and at 5, 10, and 15 minutes after intubation in patients with BIS-confirmed adequate depth of anesthesia.
Time frame: Baseline, immediately after intubation, and 5, 10, and 15 minutes after intubation
Change in Heart Rate Following Rapid Sequence Intubation
Heart Rate measured before induction, immediately after endotracheal intubation, and at 5, 10, and 15 minutes after intubation in patients with BIS-confirmed adequate depth of anesthesia.
Time frame: Baseline, immediately after intubation, and 5, 10, and 15 minutes after intubation
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.