This randomized crossover clinical trial aims to evaluate the effect of different three-dimensional (3D) printing orientations and layer thicknesses on the trueness, dimensional accuracy, and patient satisfaction of maxillary complete dentures in completely edentulous patients. Each participant will receive two maxillary 3D-printed complete dentures fabricated using the same printing orientation (0°, 45°, or 90°) with two different layer thicknesses (50 μm and 100 μm) in a crossover sequence. The study will compare the influence of these printing parameters on denture accuracy and patient-reported outcomes to identify the optimal 3D printing settings for complete denture fabrication.
This prospective randomized crossover clinical trial is designed to evaluate and compare the effect of different three-dimensional (3D) printing orientations and layer thicknesses on the trueness, dimensional accuracy, and patient satisfaction of maxillary complete dentures in completely edentulous patients. The study will include completely edentulous patients requiring maxillary and mandibular complete dentures. Each participant will receive two maxillary complete dentures fabricated using 3D printing technology with the same printing orientation but two different layer thicknesses (50 μm and 100 μm) in a crossover sequence. Participants will be randomly allocated to one of three printing orientation groups (0°, 45°, or 90°), with five participants in each group. The three printing orientations being compared are: 1. 0° Build Orientation: Maxillary denture bases will be fabricated at a 0° printing orientation using both 50 μm and 100 μm layer thicknesses. 2. 45° Build Orientation: Maxillary denture bases will be fabricated at a 45° printing orientation using both 50 μm and 100 μm layer thicknesses. 3. 90° Build Orientation: Maxillary denture bases will be fabricated at a 90° printing orientation using both 50 μm and 100 μm layer thicknesses. Each participant will wear each denture for a three-month evaluation period. The primary outcomes of the study are trueness of the printed denture bases, assessed by comparing the scanned denture base STL files with the original CAD design, and patient satisfaction, evaluated using a Visual Analogue Scale (VAS) for aesthetics, speech, masticatory efficiency, hygiene, and comfort. Dimensional deviation of the denture bases will also be assessed through three-dimensional superimposition analysis at denture insertion and after three months of use. The findings of this study will help identify the optimal combination of 3D printing orientation and layer thickness for the fabrication of maxillary complete dentures, contributing to improved manufacturing accuracy and enhanced patient satisfaction with digitally fabricated complete dentures. Primary Outcome Measures 1. Trueness of 3D-printed maxillary complete denture bases Description: To evaluate the trueness of the printed denture bases fabricated using different printing orientations (0°, 45°, and 90°) and layer thicknesses (50 μm and 100 μm). Method of assessment: The STL file of each printed denture base will be scanned using an extraoral scanner and superimposed with the original CAD design to determine trueness. Time Frame: At denture fabrication (before clinical insertion). 2. Patient Satisfaction Description: To compare patient satisfaction with dentures fabricated using different 3D printing orientations and layer thicknesses. Method of assessment: Visual Analogue Scale (VAS; 0-10) evaluating aesthetics, speech, masticatory efficiency, hygiene, and comfort. Time Frame: 15 days after insertion (baseline) and 3 months after insertion of each denture. Secondary Outcome Measure Dimensional Deviation of 3D-printed Maxillary Complete Denture Bases Description: To evaluate the dimensional stability of the denture bases fabricated with different printing orientations and layer thicknesses. Method of assessment: Three-dimensional superimposition of scanned STL files to visualize and quantify dimensional deviation. Time Frame: At denture insertion and after 3 months of clinical use for each denture.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
SUPPORTIVE_CARE
Masking
NONE
Enrollment
15
Participants will receive maxillary complete dentures fabricated using a 0° three-dimensional (3D) printing orientation. Each participant will receive two dentures printed with 50 μm and 100 μm layer thicknesses in a crossover sequence. This intervention is intended to evaluate the effect of the 0° build orientation on denture trueness, dimensional deviation, and patient satisfaction.
Participants will receive maxillary complete dentures fabricated using a 45° three-dimensional (3D) printing orientation. Each participant will receive two dentures printed with 50 μm and 100 μm layer thicknesses in a crossover sequence. This intervention is intended to evaluate the effect of the 45° build orientation on denture trueness, dimensional deviation, and patient satisfaction.
Participants will receive maxillary complete dentures fabricated using a 90° three-dimensional (3D) printing orientation. Each participant will receive two dentures printed with 50 μm and 100 μm layer thicknesses in a crossover sequence. This intervention is intended to evaluate the effect of the 90° build orientation on denture trueness, dimensional deviation, and patient satisfaction.
Faculty of Dentistry, Tanta University
Tanta, Gharbia Governorate, Egypt
RECRUITINGTrueness of 3D-printed maxillary complete denture bases
The trueness of the printed maxillary complete denture bases will be evaluated by comparing the STL file of each scanned denture base with the original CAD design using three-dimensional superimposition analysis.
Time frame: immedtiate
Patient satisfaction
Patient satisfaction will be assessed using a 10-point Visual Analogue Scale (VAS) evaluating aesthetics, speech, masticatory efficiency, hygiene, and comfort after wearing each maxillary complete denture.
Time frame: 3 months
Dimensional deviation of 3D-printed maxillary complete denture bases
Dimensional deviation will be evaluated by superimposing the scanned STL files of the denture bases to visually and quantitatively assess three-dimensional deviation after fabrication and clinical use.
Time frame: 3 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.