The purpose of this clinical study is to evaluate the preliminary safety and feasibility of using the VALSE system, which combines spinal cord stimulation with the TWIICE robotic exoskeleton, to support motor recovery and reduce reliance on laboratory-based equipment during rehabilitation in participants with traumatic spinal cord injury. The TWIICE exoskeleton is integrated through the NR system, a platform developed by EPFL. The goal is to assess the clinical safety and practical application of this combined neuroprosthetic approach in a small number of participants, in order to guide future refinements of the device and protocol, support the development of scalable interventions integrating spinal stimulation with robotic assistance, and inform strategies for delivering rehabilitation in more accessible, real-world environments.
Spinal cord injury (SCI) disrupts communication between the brain and spinal cord below the lesion, often resulting in severe and permanent motor impairments. Despite advances in rehabilitation, recovery of walking remains limited and restoring mobility is consistently identified as a top priority by individuals living with SCI. Epidural electrical stimulation (EES) of the spinal cord has emerged as a promising approach to restore movement after paralysis. By activating spinal motor circuits below the lesion, EES can enable standing, stepping, and walking in individuals with chronic SCI. ONWARD Medical has developed the ARC-IM spinal stimulation platform, which is currently being evaluated in several clinical studies, including BoxSwitch (NCT05942339), Think2Go (NCT06243952), and STIMO-BSI (NCT04632290). In the BoxSwitch trial, optimized spatiotemporal EES protocols enabled participants with chronic SCI to perform standing, stepping, and walking movements. Building on these findings, the Think2Go and STIMO-BSI studies integrated the WIMAGINE implantable electrocorticography (ECoG) system developed by Clinatec (CEA, Grenoble, France) with spinal stimulation, creating a brain-spine interface capable of decoding motor intentions and translating them into spinal stimulation. These studies demonstrated that implantable brain-spine interfaces can restore voluntary control of lower-limb movements and support functional walking after severe paralysis. Although these technologies have shown encouraging results, their use remains largely restricted to specialized rehabilitation settings. In parallel, robotic exoskeletons have been developed to support overground walking in individuals with SCI. The TWIICE exoskeleton is a lightweight and modular system specifically designed for use beyond rehabilitation centers and may complement spinal stimulation by providing functional support during walking. In this study, the investigators will evaluate the preliminary safety and feasibility of the VALSE system, which combines the ARC-IM spinal cord stimulation platform with the TWIICE robotic exoskeleton in individuals with chronic traumatic SCI. Participants will be recruited from ongoing clinical studies at Lausanne University Hospital (CHUV), including BoxSwitch (NCT05942339), Think2Go (NCT06243952), and STIMO-BSI (NCT04632290), after completion of the relevant study phases. As an early feasibility investigation, the study aims to generate preliminary safety and usability data on the combined use of spinal neuromodulation and robotic assistance during mobility tasks. The results will support the development of future neuroprosthetic solutions designed to improve walking ability, independence, and quality of life for people living with SCI.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
12
Participants will use the VALSE system, which combines the TWIICE Rise 1.0 robotic exoskeleton with epidural electrical stimulation (EES) delivered through previously implanted neuromodulation systems. The system is intended to support upright mobility and overground walking in individuals with chronic spinal cord injury (SCI) who are currently enrolled in, or have completed key phases of, neuromodulation clinical trials at CHUV, including Think2Go (NCT06243952), STIMO-BSI (NCT04632290), and BoxSwitch (NCT05942339). The TWIICE exoskeleton provides robotic gait assistance, while EES facilitates activation of spinal motor circuits below the level of injury. Exoskeleton movements are initiated and controlled through participant-generated inputs, including finger-click commands and, where applicable, brain-derived control signals from previously implanted brain-spine interface systems. The VALSE system is used in supervised clinical and controlled real-world.
Centre Hospitalier Universitaire Vaudois (CHUV)
Lausanne, Canton of Vaud, Switzerland
Preliminary safety
Occurrence of Serious Adverse Events (SAE) and Adverse Events (AE) that are deemed related or possibly related to the procedure or to the TWIICE exoskeleton in combination with the neuromodulation therapies (VALSE system)
Time frame: From enrollment until the end of study timepoint, up to 1 year after enrollment.
Assessment of the experimental session conditions
Location and type of ground walked on.
Time frame: At each in-clinic training session during the three study periods, up to 1 year after enrollment.
Number of steps
Total number of steps recorded by the exoskeleton during each experimental (EX) session.
Time frame: At each experimental (EX) session during the three study periods, up to 1 year after enrollment.
Step frequency
Average step frequency (cadence) recorded by the exoskeleton during each experimental (EX) session.
Time frame: At each experimental (EX) session during the three study periods, up to 1 year after enrollment.
Mid-stride pauses
Number of mid-stride pauses recorded by the exoskeleton during each experimental (EX) session.
Time frame: At each experimental (EX) session during the three study periods, up to 1 year after enrollment.
Distance walked
Total distance walked recorded by the exoskeleton during each experimental (EX) session.
Time frame: At each experimental (EX) session during the three study periods, up to 1 year after enrollment.
Walking time
Total walking time recorded by the exoskeleton during each experimental (EX) session.
Time frame: At each experimental (EX) session during the three study periods, up to 1 year after enrollment.
Standing time
Total standing time recorded by the exoskeleton during each experimental (EX) session.
Time frame: At each experimental (EX) session during the three study periods, up to 1 year after enrollment.
Kinematic gait parameters
Kinematic gait parameters recorded during overground walking and functional locomotor tasks (change of walking speed, stepping over and turn around obstacles, climb stairs, walk with cognitive load (e.g., counting backward by threes)) using the VALSE system.
Time frame: At each experimental (EX) session during the three study periods, up to 1 year after enrollment.
Electromyographic (EMG) activity
Muscle activation patterns recorded by surface electromyography during overground walking and functional locomotor tasks while using the VALSE system.
Time frame: At each experimental (EX) session during the three study periods, up to 1 year after enrollment.
Brain-computer interface (BCI) performance
Brain-computer interface performance metrics recorded during overground walking and functional locomotor tasks while using the VALSE system.
Time frame: At each experimental (EX) session during the three study periods, up to 1 year after enrollment.
Donning and Doffing Time
Assessment of the time it takes to put on and take off the system. Donning time is recorded from the start of preparation until the participant is fully ready for ambulation. Doffing time is recorded from the start of removal until the participant is fully disengaged from the system.
Time frame: At the last experimental (EX) session of each of the three study periods, up to 1 year after enrollment.
Level of Assistance (LOA)
Assessment to evaluates the amount of physical support required by the participant during walking and mobility activities with the device.
Time frame: At the last experimental (EX) session of each of the three study periods, up to 1 year after enrollment.
System Usability Scale (SUS)
A validated 10-item questionnaire measuring usability across multiple domains. Scores range from 0-100, with higher values indicating greater usability. Will be filled in by participants and physiotherapists.
Time frame: At the last experimental (EX) session of each of the three study periods, up to 1 year after enrollment.
ASA Task Load Index (NASA-TLX)
A 6-dimension tool assessing perceived workload (mental demand, physical demand, temporal demand, performance, effort, frustration). Will be filled in by participants and physiotherapists.
Time frame: At the last experimental (EX) session of each of the three study periods, up to 1 year after enrollment.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.