The study is planned to be conducted at multiple centers, with an intended enrollment of 326 subjects. Protocol-eligible subjects will be randomized in a 1:1 ratio to either the investigational group or the control group. The investigational group will receive a Biological Vascular Graft(LineMatrix®) manufactured by Humatrix Medical Technology (Suzhou) Co., LTD, while the control group will receive an arteriovenous graft (GORE-INTERING®) manufactured by W.L. Gore \& Associates, Inc. The primary endpoints are the Primary patency rate at 6 months postoperatively and the Cumulative Patency Rate at 12 Months postoperatively. Subjects will undergo follow-up during the screening period, at the time of AVG procedure, and at 1 month, 3 months, 6 months, and 12 months post-operatively. Safety and efficacy parameters will be observed and recorded during and after the surgery to evaluate the safety and effectiveness of the LineMatrix® Biological Vascular Graft for the creation of arteriovenous graft in patients with end-stage renal disease (ESRD).
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
326
LineMatrix® Biological Vascular Graft
GORE-INTERING®
Beijing Haidian Hospital
Beijing, Beijing Municipality, China
RECRUITINGThe First Affiliated Hospital of Chongqing Medical University
Chongqing, Chongqing Municipality, China
RECRUITINGSouth China Hospital of Shenzhen University
Shenzhen, Guangdong, China
RECRUITINGThe First Hospital of Hebei Medical University
Shijiazhuang, Hebei, China
RECRUITINGThe First Affiliated Hospital of Zhengzhou University
Zhengzhou, Henan, China
RECRUITINGTongji Hospital Affiliated to Tongji Medical Collage of Huazhong University of Science and Technology
Wuhan, Hubei, China
RECRUITINGThe Second Affiliated Hospital of Nanjing Medical University
Nanjing, Jiangsu, China
RECRUITINGThe First Affiliated Hospital of Nanchang University
Nanchang, Jiangxi, China
RECRUITINGLonghua Hospital Shanghai University of Traditional Chinese Medicine
Shanghai, Shanghai Municipality, China
RECRUITINGThe First Affiliated Hospital of Xi'an Jiaotong University
Xi’an, Shanxi, China
RECRUITING...and 2 more locations
Primary patency rate at 6 months postoperatively
Primary Patency Rate is defined as the proportion of subjects who have not experienced any of the following events from the date of vascular access creation through 6 months post-operatively: thrombosis, or any intervention performed to promote, maintain, or re-establish patency (e.g., angioplasty).
Time frame: 6 months
Cumulative Patency Rate at 12 Months Postoperatively
Cumulative Patency Rate is defined as the proportion of subjects whose vascular access has not been abandoned from the date of vascular access creation through 12 months post-operatively.
Time frame: 12 months
Primary patency rate at 3,12 months postoperatively
Primary Patency Rate is defined as the proportion of subjects who have not experienced any of the following events from the date of vascular access creation through 3,12 months post-operatively: thrombosis, or any intervention performed to promote, maintain, or re-establish patency (e.g., angioplasty).
Time frame: 3,12 months
Cumulative Patency Rate at 3,6 Months Postoperatively
Cumulative Patency Rate is defined as the proportion of subjects whose vascular access has not been abandoned from the date of vascular access creation through 3, 6 months post-operatively.
Time frame: 3,6 months
Surgical success rate
Surgical success rate is defined as the successful completion of the arteriovenous graft (AVG) surgery using the investigational device, without any device-related serious adverse events occurring during the perioperative period.
Time frame: 30 days
Time to First Cannulation
Time to First Cannulation is defined as the interval from the AVG procedure to the first hemodialysis session performed using the arteriovenous graft.
Time frame: 12 months
Device Performance Evaluation
I.Suturability Excellent: Needle passes through vessel with light touch and no deformation after arterial suturing; Good: Needle passes through vessel with light force and shows deformation after arterial suturing but can continue to be used; Poor: Needle passes through vessel with force and shows severe deformation after arterial suturing and cannot continue to be used. II.Anastomotic bleeding No: No visible blood leakage at anastomosis; Yes: Visible blood leakage at anastomosis. III.Post-cannulation hemostasis Excellent: After removal of the puncture needle, apply manual compression to achieve hemostasis; time to hemostasis is \<10 min. Good: After removal of the puncture needle, apply manual compression to achieve hemostasis; time to hemostasis is 10-15 min. Poor: After removal of the puncture needle, apply manual compression to achieve hemostasis; time to hemostasis is \>15 min, or additional hemostatic measures are required.
Time frame: 12 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.