This study aims to clinically and digitally evaluate immediate implants placed in mandibular molar extraction sockets and compare the outcomes of xenograft, e-PRF, and no grafting material within the jumping gap.
Following atraumatic extraction and implant site preparation within the interradicular bone, the implant will be immediately inserted. A chairside customized healing abutment will then be fabricated to seal the extraction socket. According to group allocation, the jumping gap will be filled with xenograft, e-PRF, or left unfilled before placement of the customized healing abutment. Definitive prosthetic restoration will be delivered after three months of implant insertion. 1. Clinical Evaluation: Implant stability will be assessed at implant placement and at 3 and 6 months using resonance frequency analysis with the Osstell device, with implant stability quotient (ISQ) values recorded. Peri-implant soft-tissue health will be assessed using the modified sulcus bleeding index (mSBI) at 3 and 6 months intervals. 2. Digital Evaluation: Peri-implant soft-tissue dimensional changes will be assessed using intraoral optical scans obtained preoperatively and at 1, 3, and 6 months. The resulting STL files will be superimposed using a best-fit alignment algorithm to evaluate dimensional changes in the peri-implant soft tissues. 3. Radiographic Evaluation: CBCT examinations will be obtained preoperatively, immediately after implant placement, and at 6 months. Three-dimensional superimposition of baseline and follow-up DICOM datasets will be used to evaluate hard-tissue dimensional changes.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Enrollment
30
after tooth extraction and implant placement, xenograft particulates were placed to fill the jumping gap before sealing the socket with a chairside socket sealing abutment.
after tooth extraction and implant placement, e-PRF was prepared from the patient's collected blood and placed to fill the jumping gap before sealing the socket with a chairside socket sealing abutment.
Faculty of Dentistry, Mansoura University
Al Mansurah, Egypt
Linear and Volumetric Digital Evaluation of implant site
Peri-implant soft-tissue dimensional changes assessment using intraoral optical scans and resulting STL files superimposition using a best-fit alignment algorithm to evaluate dimensional changes in the peri-implant soft tissues.
Time frame: preoperative, 1 month, 3 months and 6 months postoperative.
Radiographic Evaluation of Implant Site Volumetric Change
CBCT examinations obtained and three-dimensional superimposition of baseline and follow-up DICOM datasets used to evaluate hard-tissue dimensional changes.
Time frame: preoperatively, immediately after implant placement, and at 6 months
Implant Stability
Implant stability assessment using resonance frequency analysis with the Osstell device to record implant stability quotient (ISQ) values.
Time frame: at implant placement, 3 months and 6 months postoperative.
Modified Sulcus Bleeding Index
Evaluation of peri-implant soft-tissue health using the modified sulcus bleeding index (mSBI).
Time frame: at 3 and 6 months postoperative.