This study will evaluate two non-invasive ultrasound methods, transcranial Doppler (TCD) and optic nerve sheath diameter (ONSD) ultrasound, for detecting signs of increased intracranial pressure in adults with traumatic brain injury (TBI). The results of these methods will be compared with findings from brain computed tomography (CT), which will be used as the reference assessment. The study will include 40 patients aged 18 to 60 years who are admitted to the intensive care unit with blunt traumatic brain injury and diffuse brain edema on their initial CT scan. TCD and ONSD measurements will be performed by trained operators, together with collection of clinical and physiological data. The study will assess how accurately TCD and ONSD identify CT findings suggestive of increased intracranial pressure and will compare the diagnostic performance of the two methods. Measurements will also be assessed in relation to the severity of CT findings.
Study Type
OBSERVATIONAL
Enrollment
40
Transcranial Doppler ultrasound will be performed by a trained operator through the temporal acoustic window to assess the middle cerebral artery bilaterally. Measurements will be obtained at a depth of 45-60 mm, including peak systolic velocity, end diastolic velocity, and pulsatility index. A pulsatility index greater than 1.3 and end diastolic velocity less than 25 cm/s will be considered abnormal according to the study protocol.
Optic nerve sheath diameter will be measured by a trained operator using a high-frequency 5-15 MHz linear ultrasound probe. Measurements will be obtained from both eyes, with three measurements performed for each eye and the average recorded. The diameter will be measured 3 mm behind the globe with the patient supine and in a neutral head position, with the head of the bed elevated between 20° and 30°.
Ain-Shams University Hospitals
Cairo, Cairo Governorate, Egypt
Diagnostic accuracy of TCD pulsatility index (PI) and optic nerve sheath diameter (ONSD) for detecting CT signs of increased intracranial pressure Description:
Diagnostic performance of TCD-PI and ONSD measurements will be assessed by comparing them with signs of increased intracranial pressure on the initial CT brain scan. Sensitivity, specificity, positive predictive value, negative predictive value, and area under the receiver operating characteristic curve (AUC) will be calculated. The optimal cut-off values will be determined using the Youden index.
Time frame: At baseline / initial assessment
Correlation of TCD pulsatility index with severity of CT brain findings
The relationship between TCD parameters, particularly pulsatility index, and the severity of CT brain findings will be assessed using the Marshall CT classification.
Time frame: At baseline / initial assessment
Correlation of optic nerve sheath diameter with severity of CT brain findings
The relationship between ONSD measurements and the severity of CT brain findings will be assessed using the Marshall CT classification.
Time frame: At baseline / initial assessment