"Deep-learning" is a fast-growing method of machine learning (artificial intelligence, AI) which is arousing the interest of the scientific committee in many medical fields. These methods make it possible to generate matches between raw inputs (such as the digital signal from the ECG) and the desired outputs (for example, the measurement of QTc). Unlike traditional machine learning methods, which require manual extraction of structured and predefined data from raw input, deep-learning methods learn these functionalities directly from raw data, without pre-defined guidelines. With the advent of big-data and the recent exponential increase in computing power, these methods can produce models with exceptional performance. The investigators recently used this type of method using multi-layered artificial neural networks, to create an application based on a model that directly transforms the raw digital data of ECGs (.xml) into a measure of QTc comparable to those respecting the highest standards concerning reproducibility. The main purpose of this trial is to study the performance of our DL-AI model for QTc measurement (vs. best standards of QTc measurements, TCM) applied to the recommended ECG monitoring following ribociclib prescription for breast cancer patients in routine clinical care. The investigators will acquire ECG with diverse devices including simplified devices (one/three lead acquisition, low frequency sampling rate: 125-500 Htz) to determine if they'll be equally performant versus 12-lead acquisition machine to evaluate QTc in this setting.
Study Type
OBSERVATIONAL
Enrollment
70
Patients will have three visits during the cycle for a given dose (600mg/day, 400mg/day or 200mg/day): Baseline , Day 14, Day 28 At each visit, the patient will have the acquisition of a digitized ECG by four modalities within 20 minutes (A 10 second triplicate ECG with WELCH-ALYN ELI-280® with the three 10 sec ECGs collected at approximatively 2-minute intervals, 3 min holter acquisition with a CGM HI-patch ®, a 3 minutes acquisition with AliveCore 6L® device and 10 seconds triplicate acquisition with QT-medical ® device collected at approximatively 2-minute intervals ). Concomitantly with the ECG acquisition, patients will have blood sampling for measurements of variables clinically important for assessment of QTc including potassium, fasting blood glucose, calcemia, magnesium, estradiol, progesterone, FSH, LH, D4-androstenedione, total and free testosterone, SHBG and TSH. Blood concentration of ribociclib will be also assessed.
Groupe Ambroise Paré, Hartmann
Neuilly-sur-Seine, France
Hôpital Tenon
Paris, France
CIC - Hôpitaux Universitaires Pitié Salpêtrière, Paris, FRANCE
Paris, France
Institut Gustave Roussy
Villejuif, France
Compare the values of QTc generated by method 1 (overlap method on triplicate of 10 seconds ECG concatenated, TCM; the method of reference) versus method 2 relying on AI methodology in patients' candidate for ribociclib start
Comparison of the 2 methods (TCM vs. DL-AI) to demonstrate if there is a clinically relevant mean QTc difference ≥ 5msec between the 2 methods.
Time frame: One visit the day of ribociclib start (before ribociclib intake)
Compare the values of QTc generated by method 1 (overlap method after triplicate concatenation, TCM) versus method 2 (DL-AI) in patients' on/off ribociclib using a digitized 12-lead acquisition ECG device
Bland-Altman plots and intra-class correlation will be generated to compare QTc values obtained by TCM vs. DL-AI on ribociclib (Day 14+/-3 days after start) and off-ribociclib (Day 28 +/-3 of ribociclib cycles).
Time frame: One visit at day 14+/-3 and day 28+/-3 after start of ribociclib
Compare the values of QTc generated using method 2 (DL-AI) in patients' on/off ribociclib using a miniaturized and/or simplified ECG acquisition device (QT-Medical®, AliveCor®, a holter system (CGM HI-patch) versus using a digitized 12-lead acquisition
Compare QTc values obtained by DL-AI on/off ribociclib using a standard digitized 12-lead acquisition device (WELCH-ALYN ELI-280) versus each of three other miniaturized and/or simplified ECG acquisition devices (QT- Medical®, AliveCor®, CGM HI-patch®).
Time frame: One visit at baseline before ribociclib start and then day 14+/-3 and day 28+/-3 after ribociclib start
The clinico-demographic predictors of amplitude of QTc prolongation on ribociclib.
Nonlinear mixed models will be used to study clinico-demographic determinants associated with magnitude of QTc prolongation on ribociclib.
Time frame: One visit at baseline before ribociclib start and then day 14+/-3 and day 28+/-3 after ribociclib start
Learn ECG features at baseline using deep-learning predictors of magnitude of QTc prolongation on ribociclib
Using deep-learning seeking for a model using ECG raw data at baseline to predict magnitude of QTc prolongation on ribociclib
Time frame: One visit at baseline before ribociclib start and then day 14+/-3 and day 28+/-3 after ribociclib start